Left Side
- Position the blend door actuator (1) to the blend door cam (3).
- Install the blend door actuator onto the left side of the HVAC air distribution housing (4). If necessary, rotate the actuator slightly to align the splines on the actuator output shaft (2) with those on the blend door cam (3).
- Install the two screws (4) that secure the blend door actuator (1) to the air distribution housing (3) and securely tighten.
- Connect the HVAC wire harness connector (2) to the blend door actuator.
- Install the steering column. Refer to COLUMN, INSTALLATION .
- Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.
- Initiate the Actuator Calibration function using a scan tool. Refer to STANDARD PROCEDURE .