Transducer, A/C Pressure: Installation
NOTE:
Use only the specified O-ring as it is made of special material for this system. Use only refrigerant oil of the type required for the A/C compressor.
- Lubricate a new rubber O-ring seal with clean refrigerant oil and install it onto the liquid line fitting.
- Install the A/C pressure transducer (2) onto the Internal Heat Exchanger (1) and securely tighten the A/C pressure transducer (2).
- Connect the wire harness connector (3) to the A/C pressure transducer (2).
- Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.